@davidgerard @Unixbigot @catsalad to put this number in actual perspective:
The annual rainfall in Florida is about 56 inches. USGS' calculator only lets you use 50.
So less than the annual rainfall in Florida is 46,596,264,000,000 gallons. Google is admitting to using 2,920,000,000 gallons per year before waste and losses.
That's over 6% of all annual rainfall. In FLORIDA.
That is more than enough to put aquifers into terminal decline.
(edit: yush math is wrong, I mathed pre-coffee.)
@jeffreyolivier @davidgerard @Unixbigot @catsalad yeah, doesn't surprise me, pre-coffee and thrown into Excel.
But it's a not insignificant number to say the least. NEORSD is one of the largest systems in the country and treats 200M gallons per day. A single Google datacenter *consumes* >4% of that. (The consume is important.)
So at 73 admitted data centers that's >584M GPD burned. I did the full math with other use but I think those notes are on the dead PC.
@jeffreyolivier @davidgerard @Unixbigot @catsalad a better comparison is probably this:
In 2020 the entire nuclear power industry withdrew (used) 42,045MG per day using the most pessimistic numbers. But actual *consumption* (loss) was 946MGD. Or ~2.2%. The remaining 97.8% is returned to the water table and a small portion of the 2.2% is evaporative.
73 Google data centers consume a minimum of 671MGD, or more than 70% of the entire nuclear power industry in the United States.
@rootwyrm @jeffreyolivier @Unixbigot @catsalad in practice with data centres, "returned to the water table" means "doing the minimum you can get away with before dumping it, down to nothing at all if you don't think you'll get caught"
just pumping the water back into the stream, but now it's contaminated and 40 deg C
@davidgerard @jeffreyolivier @Unixbigot @catsalad to give some idea on good vs. bad: Dell C6525's are probably over 80/20 fluid/air at 5.2kW/2U. Very respectable numbers, fairly well designed. (Should've used a monoblock design for several reasons.)
Most of the A100 SXM boards I've been able to look at are using the *same* blocks in series with over 200W of *fan* draw just for the power section.
@davidgerard okay my brain's gotta go into mono vs modular.
Basically, per-die blocks are only locally efficient and create risk points (leaks.) All your power heat (which is SUBSTANTIAL) is left to be cooled by air. Which takes a LOT of power in fans.
The reason power stages were typically left to air was because you were talking minimal waste heat. 300W (AMD) TDP EPYCs are fine with dinky little aluminum sinks and 200-300LFM! Hell, 300W CPUs are doable with air alone.
@davidgerard
I can see that manufacturing tends to leave waste in the outflow, but what do we look for in data centre cooling outflows?
I'd seen the cooling described as evaporative, which suggests that the water returns to the ground via a cloud, downwind somewhere. That's not necessarily helpful I suppose.
@Photo55 from the watercooled bitcoin data centres, oily crap seems like
the 40 deg C water being pumped back into the stream is the biggest problem though
I was under the impression that many days centres don't pump any water back into the stream: they evaporate it all. I did a back-of-envelope to estimate how much water a 1GW DC might need to boil off and, FWIW, it came out at 33 megalitres per day.
https://infosec.space/@CppGuy/115944454840789065
Goodness knows what that does to the local microclimate.

Attached: 1 image @[email protected] We can get an idea of the scale by thinking back to school physics Suppose the data centre evaporates water to shed heat. Suppose the water arrives at 20°C. Then heating up a litre of water to 100°C takes 80*4200 joules, and evaporating it takes a further 2.26MJ. So the total amount of energy that the DC can dump into one litre of water is (80*4200 + 2260000) joules. https://en.wikipedia.org/wiki/Specific_heat_capacity https://www.bbc.co.uk/bitesize/guides/zcncjty/revision/5 A 1GW DC has to dump 1GJ of heat per second, or 24*3600*1GJ per day. Divide the second number by the first, as we find that a 1GW data centre will evaporate roughly 33 megalitres — that is, 33,000 tons — of water per day.
@davidgerard seems inefficient design. Cooling the water, oil, glycol, etc against a stream or air, and recirculating it seems sensible.
I'm assuming they filtered the newts and weed out of it to start with, why have to do that again.
40°C seems a bit cool, also given working temperatures of 85°C or so. Is this water sprayed over coils in a heat exchanger? If so, a pump that leaked oil detectable short of sensitive assay is not long for duty, I think. And we pump drinking water, don't we.